MySpace
  • Home
  • Profiles ▼
  • Communities ▼
  • Apps ▼
  • Metrics
  • Moderation
  • ▼
  • Log In
  • Share
  • ?
  • HCLHCL

Communities

This community can have members from outside your organization. SLICKLINE

  • Log in to participate
392ae21d-2fb9-40f5-8d08-ebe48354171d Blog

▼ Tags Topic Tags

 

▼ Similar Entries

WAX CLEANING WITH SLICKLINE

Blog: SLICKLINE
Vmds Teja 21E59B38-7118-8092-6525-830B0037B027 teja_vmds@ongc.co.in
Updated
1 people likes thisLikes 1
No CommentsComments 0

TREE SAVER SEAL FISHED DURING ...

Blog: SLICKLINE
Vmds Teja 21E59B38-7118-8092-6525-830B0037B027 teja_vmds@ongc.co.in
Updated
1 people likes thisLikes 1
No CommentsComments 0

▼ Archive

  • September 2025

▼ Blog Authors

SLICKLINE

View All Entries
Clicking the button causes a full page refresh. The user could go to the "Entry list" region to view the new content.) Entry list

COMBUSTION INSIDE WELL WHILE DOING SLICKLINE

Vmds Teja 21E59B38-7118-8092-6525-830B0037B027 teja_vmds@ongc.co.in | | Tags:  #domainexpertise #slickline #sharing ‎ | 1 Comment ‎ | 175 Views

Combustion inside Well lead to fishing :

While doing wax cleaning job, tool snapped suddenly and wire started coming with black texture. Observed wire size reduced at snap point drastically and wire felt very hot. 

Cause:  Established root cause for the incident after observing snapped wire and well time line. The previous day an air compressor job was performed to lift oil from the well through GLV. But prolonged air injection emptied liquid column inside tubing leaving air inside. As time progressed gas migrated to empty column and formed mixture of air and gas. While doing slicklkne job, tools might have generated necessary spark over course of job and ignited gas leading to melting of wire and snap. 

 

Lesson to be learnt : Air compressor application with out knowledge of liquid column present in well can form dangerous air fuel mixture which is ready to ignite. Operators and Job supervisors are to be made aware of the risk involved in compressor application and plan necessary risk mitigation measures before performing the well intervention jobs.

Modified on by Vmds Teja 21E59B38-7118-8092-6525-830B0037B027 teja_vmds@ongc.co.in
  • Add a Comment Add a Comment
  • Edit
  • More Actions v
  • Quarantine this Entry
Notify Other People
notification_ex

Send Email Notification

Quarantine this entry

deleteEntry
duplicateEntry

Mark as Duplicate

  • Previous Entry
  • Main
  • Next Entry
Feed for Blog Entries | Feed for Blog Comments | Feed for Comments for this Entry
  • Home
  • Help
  • Bookmarking Tools
  • Mobile UI
  • About
  • HCL Connections on hcl.com
  • Submit Feedback